0.6/1KV VV23-Copper Conductor PVC Insulated Steel Tape Armoured PE Sheathed Power Cable

0.6-1KV VV23 1~4 core Copper Conductor PVC Insulated Steel Tape Armoured PE Sheathed Power Cable Cross Section

1-4 Core CU/PVC/PVC/STA/PE Cross Sectional Structure Picture For 0.6/1KV

0.6-1KV VV23 3+1 core Copper Conductor PVC Insulated Steel Tape Armoured PE Sheathed Power Cable

3+1 Core CU/PVC/PVC/STA/PE Power Cable For 0.6/1KV

0.6-1KV VV23 3+2 core Copper Conductor PVC Insulated Steel Tape Armoured PE Sheathed Power Cable

3+2 Core CU/PVC/PVC/STA/PE Power Cable For 0.6/1KV

0.6-1KV VV23 4 core Copper Conductor PVC Insulated Steel Tape Armoured PE Sheathed Power Cable

4 Core CU/PVC/PVC/STA/PE Power Cable For 0.6/1KV

0.6-1KV VV23 4+1 core Copper Conductor PVC Insulated Steel Tape Armoured PE Sheathed Power Cable

4+1 Core CU/PVC/PVC/STA/PE Power Cable For 0.6/1KV

APPLICATION
VV23-Copper Conductor PVC Insulated Steel Tape Armoured PE Sheathed Power Cable.
This product is suitable for using in power distribution networks or fixed installations for industrial equipments with rated voltage up to and including 0.6/1KV.

CABLE STANDARDS
GB/T12706-2008,IEC,BS,ASTM and etc. upon request.

18

 

 

BASIC INFORMATION
Code Name
VV23
Rated Voltage (Uo/U)
0.6/1KV
Cable Structure
Copper Conductor/PVC Insulation/PVC Inner Sheath/Steel Tape Armoured/PE Outer Sheath

CONSTRUCTION
Conductor
Number of conductors:1,2,3,4,5,3+1,4+1
The conductors shall comply with the requirement given in IEC
Insulation
PVC(Polyvinyl Chloride) according to IEC
Inner Sheath
PVC(Polyvinyl Chloride) according to IEC
Outer Sheath
PE(Polyethylene)according to IEC
Armoured
Steel Tape

CHARACTERISTICS
Conductor temperature
Maximum conductor temperature in normal use: 70℃
Max.short-circuit temperature
Maximum shall not exceed 160℃(5s Max,Duration)
Installation temperature
Ambient temperature under installation shall not be below 0℃
Minimum bending radius
The bending radius of cable: (D-Diameter of cable)
————————————-≥15D

PRODUCTION RANGE

NO. Of CoresNominal Cross Sectional Area m²
1*10-800
24-400
34-630
44-500
3+14-630
54-500
4+14-500
3+24-500
Nominal Cross Sectional Area(mm²)NO.of CoresNominal Insulation Thickness(mm)Approx Overall Diameter(mm)Cable Weight Max(kg/km)
101111.5253
161112.5328
2511.214.3453
3511.215.4565
50*11.416.6723
70*11.418.4956
95*11.620.41260
120*11.621.81464
150*11.823.61796
185*1225.72107
240*12.228.32680
300*12.431.23695
400*12.634.34655
500*12.839.45806
630*12.844.57065
800*12.951.38935
42114.1304
62115.1367
102117.4495
162119.4655
2521.223929
3521.225.21172
50*21.427.61293
70*21.431.41999
95*21.6372627
120*21.6403147
150*21.8443891
185*2248.44645
240*22.255.26460
300*22.460.68011
43114.7363
63115.8447
103118.3620
163120.5840
2531.224.31213
3531.226.71551
50*31.429.51844
70*31.433.62818
95*31.639.53741
120*31.642.74521
150*31.8475489
185*3251.76702
240*32.257.78555
300*32.463.910524
400*32.671.214053
44115.8434
64117542
104119.8764
164122.31048
2541.226.61529
3541.229.51969
50*41.433.62703
70*41.439.53616
95*41.644.74845
120*41.648.35866
150*41.852.97124
185*4258.38702
240*42.26511097
300*42.471.913693
400*42.681.418282
45117508
65118.4651
105121.5924
165124.21276
2551.229.11871
3551.232.52755
50*51.437.33460
70*51.442.44566
95*51.648.26188
120*51.652.17524
150*51.857.49303
185*5263.510739
240*52.270.914083
300*52.478.817685
400*52.68923388